Shopping security
The MOXI Fusion A.P.T. Control Unit works by gently moving air through the mattress in a steady rhythm. It sends air into different sections of the mattress and then releases it in cycles to keep the surface balanced.
The unit senses changes in pressure and automatically adjusts the airflow to stay at the right level. This helps the mattress stay firm enough for support but soft enough to reduce strain on the body. The motor runs quietly so the user can rest without being disturbed.
The Fusion A.P.T. Control Unit powers the Fusion A.P.T. Mattress System by moving air through its internal air cells in a steady rhythm. It follows a timed 10-minute cycle that gently inflates and deflates the mattress sections to keep the surface balanced and responsive. The control unit also checks and adjusts air pressure automatically to match the user’s needs.
Keeps air pressure steady for balanced support
Lets the user adjust how firm or soft the mattress feels
Has options for moving or steady air flow
Air cells change every 10 minutes for gentle movement
Checks and keeps the right air pressure automatically
Shows a light and sound alert if air pressure gets low
Runs quietly so the user can rest without noise
Keeps air in the mattress for up to 24 hours if power goes out
| General | |
|---|---|
| Model Name | Fusion A.P.T. Control Unit |
| Reference No. | FC-MOX1007 |
| Size (L × W × H) | 10.1” × 4.5” × 8.3” |
| Weight | 4.85 lbs |
| Cycle Time | 10 minutes |
| Pressure & Power | |
| Minimum Operating Pressure | 18 ± 6 mmHg |
| Maximum Operating Pressure | 50 ± 6 mmHg |
| Rated Voltage | AC 110–120V |
| Rated Frequency | 60 Hz |
| Fuse Rating | T1AH 250V |
| Maximum Current | 0.1A |
| Classification | Class II, Type BF Not AP or AGP type |
| Ingress Protection Rating | IP21 |
| Mode of Operation | Continuous |
| Power Cable | 15ft, non-shielding, AC powered |
| Environmental Conditions | |
| Operating Temperature | 15°C to 35°C (59°F to 95°F) |
| Storage Temperature | 5°C to 60°C (41°F to 140°F) |
| Operating Humidity | 15% to 90% (non-condensing) |
| Operating Atmospheric Pressure Range | 800 hPa to 1060 hPa |
| Operating Altitude | 0 meters to 2000 meters |
| Standards | |
| Compliance | IEC 60601-1 CAN/CSA C22.2 No. 60601-1 IEC 60601-1-2 IEC 60601-1-11 |