20% OFF shipping at mein-werk.net on orders over $79 + up to 10% OFF products
mein-werk.net
home > coal gasifier atmos kc45s 45 kw > coal gasifier atmos kc45s 45 kw
download picture
coal gasifier atmos kc45s 45 kwProduct Overview & Application The Atmos KC45S coal gasifier is a manually loaded solid fuel boiler with a rated heat output of 45 kW, designed for heating systems with a correspondingly high heat demand. It is intended for operation with lignite briquettes and, according to the manufacturer, can also be operated with dry split logs as an alternative fuel. The boiler is suitable for residential buildings, weekend houses, and similar properties where a
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview & Application

The Atmos KC45S coal gasifier is a manually loaded solid fuel boiler with a rated heat output of 45 kW, designed for heating systems with a correspondingly high heat demand. It is intended for operation with lignite briquettes and, according to the manufacturer, can also be operated with dry split logs as an alternative fuel.

The boiler is suitable for residential buildings, weekend houses, and similar properties where a robust solid fuel heat generator is to be integrated into a water-based heating system. The specific design of the system, the chimney, and the storage or return flow technology should always be tailored to the building and the existing heating system.

Technology & Equipment

The Atmos KC45S operates on the principle of gasification and uses an induced draft fan to support the combustion and flue gas path. The fuel loading chamber is equipped with a rotating grate mechanism and secondary air supply in the lower section, while the combustion chamber is lined with ceramic elements.

Operation is controlled via electromechanical equipment including a thermometer, main switch, flue gas thermostat, boiler thermostat, and safety thermostat. A cooling loop is provided for overheating protection. This makes the boiler technically designed for operation with solid fuels and the typical requirements of a boiler room.

Everyday Advantages

The rotating grate mechanism facilitates the downward movement of ash into the combustion chamber and supports practical cleaning during solid fuel operation. The large loading opening and the fuel shaft with a volume of 125 liters are tailored for operation with lignite briquettes and the intended alternative fuels.

Thanks to the electromechanical basic equipment, the operating logic remains clear. At the same time, the induced draft fan, ceramic combustion chamber, and preheated primary and secondary air support a stable combustion process within the intended operating range.

System Integration & Compatibility

The Atmos KC45S is integrated into a water-based heating system and requires a suitable chimney with sufficient draft. The flue pipe connection is designed for 150/152 mm, and the required chimney draft is 25 Pa.

For safe and boiler-friendly operation, the return temperature, operating temperature, chimney connection, and hydraulic integration must be professionally planned. The manufacturer's documentation specifies a minimum return temperature of 65 °C and a design operating temperature of 80 to 90 °C.

Technical Specifications at a Glance

The following technical data refers to the Atmos KC45S and is limited to the active META fields relevant to the shop.

Rated Output 45 kW
Fuel Lignite briquettes; dry split logs as alternative fuel
Combustion Technology Coal gasifier / gasification
Efficiency 85.2 %
Energy Efficiency Class C
Max. Operating Pressure 2.5 bar
Log Length 430 mm
Boiler Class 4
Draft Requirement 25 Pa
Flue Gas Temperature 254 °C
Flue Pipe Connection 150/152 mm
Safety Heat Exchanger Cooling loop for overheating protection
Height 1435 mm
Width 675 mm
Depth 858 mm
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W

Installation

Installation of the Atmos KC45S involves integration into a water-based heating system with a suitable installation room, appropriate chimney connection, and a professionally executed electrical connection. The boiler is designed for connection to 230 V / 50 Hz.

When planning the system, particular attention must be paid to chimney draft, flue pipe routing, return temperature boosting, overheating protection, and hydraulic integration. The work should be carried out by a qualified specialist company.

Notes

Lignite briquettes are intended as the main fuel. Dry split logs can be used as an alternative fuel if the manufacturer's specifications regarding moisture content, diameter, and length are observed.

The prescribed minimum return water temperature is 65 °C. The design operating temperature of the boiler is 80 to 90 °C. The choice of output does not replace a heat load calculation and should be verified as suitable for the building and the existing heating system.

Scope of Delivery

  • Atmos KC45S coal gasifier
  • Steel brush with accessories, 1 piece
  • Poker, 1 piece
  • Filling valve, 1 piece
  • Operating and maintenance manual, 1 piece
  • Draft regulator HONEYWELL FR 124, 1 piece
  • Ash container, 1 piece

coal gasifier atmos kc45s 45 kw

Item no : 16205270234
sold recently : Login >>
US$ 2633.11
Pay in 4 interest-free payments of $658.28 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 1 - Aug 6

Enjoy 20% off shipping

US$ 2633.11

1-11

US$ 2369.80

12-35

US$ 1843.18

36-59

US$ 1579.87

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches