20% OFF shipping at mein-werk.net on orders over $79 + up to 10% OFF products
mein-werk.net
home > atmos gs 20 20 kw wood gasification boiler > atmos gs 20 20 kw wood gasification boiler
download picture
atmos gs 20 20 kw wood gasification boilerProduct Overview & Application The Atmos GS 20 wood gasification boiler is a manually fed hot water heating boiler for split logs, designed for heating single family homes and similar properties. The unit operates on the wood gasification principle with an exhaust fan, which supports stable combustion and controlled heat output typical of this design. With a nominal output of 20 kW, this model is suitable for systems requiring a classic log boiler
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview & Application

The Atmos GS 20 wood gasification boiler is a manually fed hot water heating boiler for split logs, designed for heating single-family homes and similar properties. The unit operates on the wood gasification principle with an exhaust fan, which supports stable combustion and controlled heat output typical of this design. With a nominal output of 20 kW, this model is suitable for systems requiring a classic log boiler with clear, robust technology.

Technology & Features

The boiler is designed for burning dry split logs. Combustion occurs using the downdraft gasification principle with an exhaust fan. The boiler body is made of steel sheets, and the secondary combustion chamber is equipped with ceramic components. Features include a boiler thermostat, flue gas thermostat, flow temperature thermometer, main switch, and mechanical operation of the start-up flap. A cooling loop is also included for protection against overheating.

Everyday Advantages

In practical operation, the Atmos GS 20 offers robust and straightforward boiler technology without unnecessary complexity. The large combustion chamber allows the use of split logs up to 330 mm in length. The wood gasification principle with preheated primary and secondary air supports even flame formation. Users will also appreciate the clear control layout, good accessibility for cleaning, and the electromechanical control system tailored to this boiler type.

System Integration & Compatibility

The Atmos GS 20 should be integrated into a professionally planned heating system with a buffer tank. The documentation explicitly recommends installation with a buffer tank and Laddomat 22 or a suitable return temperature boosting system to maintain the minimum return temperature and ensure clean operation. A minimum return temperature of 65 °C must be maintained for the boiler circuit, with the flow temperature set between 80 and 90 °C. For boiler outputs of 15 to 25 kW, pipe connections to buffer tanks should be made using 28x1 mm copper or 25 mm steel pipes.

Technical Specifications at a Glance

The following technical data for the Atmos GS 20 is clearly documented in the available materials.

Nominal Output 20 kW
Fuel Wood
Combustion Technology Wood Gasification
Efficiency 91.4 %
Energy Efficiency Class A+
Max. Flow Temperature 90 °C
Max. Operating Pressure 2.5 bar
Log Length 330 mm
Boiler Class 5
Draft Requirement 20 Pa
Flue Gas Temperature 134.7 °C
Flue Pipe Connection 150/152 mm
Safety Heat Exchanger Yes
Buffer Tank Recommended Yes
Height 1260 mm
Width 680 mm
Depth 845 mm
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W

Installation

Installation must be carried out in accordance with applicable regulations and based on professional system planning. The boiler must be placed in a boiler room with an adequate supply of combustion air; for systems between 15 and 75 kW, the documentation specifies a combustion air opening of at least 350 cm². A foundation dimension of 700 x 600 mm is recommended for the GS 20. The connection to the chimney must be professionally executed, and the flue pipe connection should be as short as possible, rising, and no longer than 1 m.

Notes

Only dry split logs or chopped wood with a residual moisture content of 12 to 20 % should be used for operation. Fresh or overly damp wood impairs combustion and can negatively affect performance, consumption, and the lifespan of the boiler and chimney. When lighting the fire, set the flue gas thermostat to 0 °C; during operation, set it to the normal working range. According to the documentation, the boiler thermostat should be set to approximately 85 to 90 °C. Operation, connection, and electrical work must be carried out by qualified personnel.

Scope of Delivery

  • Atmos GS 20 Wood Gasification Boiler
  • Steel Brush with Accessories
  • Poker
  • Fill Valve
  • Operating and Maintenance Manual
  • Honeywell FR 124 Draft Regulator
  • Ash Pan

atmos gs 20 20 kw wood gasification boiler

Item no : 85047221856
sold recently : Login >>
US$ 2312.24
Pay in 4 interest-free payments of $578.06 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 8 - Aug 13

Enjoy 20% off shipping

US$ 2312.24

1-11

US$ 2081.02

12-35

US$ 1618.57

36-59

US$ 1387.34

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches